- Screen display: 4-digit, seven-segment display.
- Temperature monitor point configuration: point 1 to 8/24 temperature.
- Number of monitoring points: 1 set of software can monitor 24/32/48/56... points.(expandable to unlimited Tag for optional).
Temperature range: -270 to 1372°C (Type K)/ +/- 200°C (Pt(RTD)).
(Medical use! The temperature range can be tested and calibrated according to SGS)
Sensor Probe length: 5 to 40 meters, K type thermocouple/Pt (RTD) placed in a glycol bottle.
(Probes above 40 meters need to be customized)%RH(humidity)/CO2(carbon dioxide)/DP(pressure difference)/LEL/Vol%/PPM/dB for optional.
- Accuracy and resolution (K type thermocouple/Pt (RTD)): ± 0.1℃(-200℃ to 200℃); 0.1℃(SGS/TAF:ECAC2387717).
- Data logger: The network system connection is disconnected, such as network disconnection, abnormal system connection receiving data, failure to send, etc. CTMS-Pro-W/E-Log can automatically implement the record replenishment mechanism (the Data Logger high-speed computing microprocessor (MCU) has the function of actively transmitting data back to the host): automatically read the missing reading values from the on-site monitoring equipment.
- Reaction time: 63% of the total reaction temperature change within 30 seconds.
- Working environment of temperature control box: humidity 10 to 95% and no condensation; temperature -15 to 70℃ (SGS/TAF: HC10047/2018).
- Temperature-controlled box storage environment: humidity 5 to 95% and no condensation; temperature -25 to 80°C
- (SGS/TAF: HC10047/2018).
- Software functions: personnel management, real-time monitoring (when the controller abnormal message occurs, real-time triggering can be set (4 times/1s), Alarm notification, output report, The system has automatic storage function, instrument difference(offset) correction, abnormal remarks, and can automatically store 15,000 pieces of data from on-site monitoring equipment.
- Personnel management: Chinese interface; different levels of user passwords can be set.
- Real-time monitoring: The temperature control box automatically measures the temperature and regularly transmits the data back to the system. It can also be monitored through WEB or APP.
- Storage capacity: There is no limit to the number of data stored, and a backup database can be set.
Alarm notification: a) Temperature control box: When the temperature is abnormal, the red light flashes as a warning and the buzzer sounds.
b) Software: Automatic alarms are sent to default notification targets. Free emails or emails are sent when the hospital network system is connected. By purchasing a text message machine, you can send text messages(SIM card must be provided by the user) or Line Notify. c) Alarm delay setting and high and low temperature alarm setting.
Alarm types: a) Temperature control box: abnormal temperature alarm sound;
b) System: abnormal temperature, disconnection notification.
- Alarm mute: The temperature control box has an alarm switch button, and the software also has an alarm mute button, and the reset time can be set become infinite.
- Reset notification: After the point returns to normal, the manager will be notified of the cause of the alarm and the recovery status.
- Output report: Users can select the date range and output the report with the start and end time.
- Report recording interval: can be customized according to needs from 1 minute to 2 hours.
- Floor plan sensor location (Optional)
WiFi type: Antenna type: External.
Wireless band: 2.4 GHz
Wireless encryption mode: WEP/AES/WPA2
Signal strength and transmission speed: less than 40mW, 54 Mbps.
Wireless transmission range: In an environment with no interference sources and no obstacles, the transmission distance can reach up to 90 meters.
Equipped with Modbus RTU to MQTT JSON
Equipped with Modbus RTU to Modbus TCP
Equipped with RS-485 to WIFI, RS485 to Ethernet
Expandable LoRa to WIFI, LoRa to Ethernet
Subscriber/Publisher(MQTT-optional)
Ethernet type: Ethernet port type: RJ45 external type.
Ethernet speed: 10/100 Mbps (auto-detection).
Ethernet protection: 1.5KV protective magnetic isolation.
Equipped with Modbus RTU to Modbus TCP
RS485 type: RS485 serial port type: RS485/ Modbus RTU serial port external type.
RS485 serial port speed: 1300 ~115k bps
RS485 serial port protection: 3000V protection photoelectric isolation.
- Power transformer: 2 meters; input) 100~240 VAC to output) 12VDC/4.16A
- Report recording interval: can be customized from 1 minute to 24 hours according to needs
- Dimensions and weight: 10.4 (length) cm x 6.8 (width) cm x 10 (height) cm; 0.46 kg.
- Shell color: metal hairline aluminum shell; wall mount with keyhole design, safe, shockproof and anti-falling.
- Certification: TAF, SGS, ROHS, FCC Part 15, CE
System host and peripherals: 1. CPU Intel i3/i5 dual core or above 2. RAM: 8G or above
3. Dual hard drive 240G 4. WIN 10 genuine 5. 22” LCD monitor 6. UPS uninterruptible power supply system 7. Keyboard & Mouse
- Accessories in the box: power transformer, user manual, quick start guide
Cold Chain